Materials · Fitting material

CPVC (Chlorinated PVC) Chemical Resistance

CPVC has chemical resistance comparable to PVC but handles hotter liquids, so we use it when a tank stores a corrosive liquid that runs warmer than PVC allows.

TemperatureHandles corrosive fluids at temperatures up to 210°F. (Source: Harrington Industrial Plastics, Basic Materials Guide)
What to watch forChemical resistance is comparable to PVC, so the same families (ketones, aromatics, some chlorinated hydrocarbons) are the ones to check. (Source: Harrington Industrial Plastics, Basic Materials Guide)
Where we use itBulkhead flanges (ANSI 150) with van stone flanges and pipe nipples for hotter corrosive service.

Schedule 80 CPVC, never Schedule 40

Our CPVC pipe nipples and fittings are Schedule 80, the heavy-wall grade under ASTM F441, which covers CPVC pipe in Schedules 40 and 80. Schedule 80 has the same outside diameter as Schedule 40 but a thicker wall, so it holds more pressure and has the wall needed for threaded connections. CPVC is chosen for hot corrosive liquids, where plastic is already working closer to its limits, so we use the heavier Schedule 80 wall for industrial safety rather than the thinner Schedule 40. (Source: Engineering ToolBox, ASTM D1785 and ASTM F441 PVC and CPVC pipe dimensions; Westlake Pipe & Fittings, Schedule 40 vs Schedule 80 PVC)

Chemicals rated for CPVC

Ratings from the Bailiff chemical compatibility chart. Click a chemical for its full ratings across tank resins, fittings, gaskets and metals.

Excellent (97)

Request a QuoteAll materials

Ratings are a general guide. Chemical resistance depends on temperature, concentration, mixtures and exposure time. Contact us before storing any chemical rated Fair or Not Recommended, and send us the safety data sheet for a recommendation.

★ Tank Wizard