Home › Fittings & Options › Heat Tracing
Heat trace pads on the tank wall, under the insulation, keep the liquid from freezing and hold it at the temperature your process needs.
The main job of heat trace on a plastic tank is freeze protection. Water-based chemicals, fertilizers and process fluids can freeze at or near 32°F (0°C), which can damage the tank, crack fittings or block outlets. Heat trace keeps the contents above the freezing point.
Some liquids, such as adhesives, surfactants and certain agricultural chemicals, thicken or solidify in cold weather and become hard to pump. Heat trace holds them at a temperature where they pump and meter consistently.
Heat trace is always installed with spray foam insulation. The pads are attached to the tank, then the foam is sprayed over them and sealed with a white mastic coating. See tank insulation.
We bond HTD Heat Trace SPX heating pads to the sidewall of the tank and wire them to a 2XTC controller. The controller holds your setpoint, and a separate high-limit sensor keeps the pads from ever overheating the plastic. Pads run at 0.39 watts per square inch and can hold liquid up to 150°F; complete systems run from 210 W to 4,200 W.


| Power | SPX 210: 210 W · SPX 420: 420 W |
|---|---|
| Size | 30″ × 18″ (210) · 60″ × 18″ (420) |
| Watt density | 0.39 W/sq. in. |
| Voltage | 120 VAC (240 VAC on request) |
| Max. maintain temp. | 150°F (66°C) |
| Max. exposure temp. | 220°F (104°C) |
| Min. install temp. | 50°F (10°C) |
| Min. tank diameter | 36″ (18″ bend radius) |
| Construction | Multi-path parallel circuit in waterproof epoxy-glass laminate, aluminum ground shield |
| Protection | Internal over-temperature thermostat |
| Cold lead | 3-conductor 16 AWG, TPE jacket, tinned copper braid; available in 10, 16, 20 or 24 ft (SPX 420) |
| Mounting | Adhesive back; edges sealed with aluminum tape |
| Power input | 100–277 VAC, 50/60 Hz |
|---|---|
| Heater output | 30 A SPST relay, active arc suppression |
| Process setpoint | 0–200°F, on/off with adjustable band |
| High limit | 0–250°F, separate sensor |
| Alarms | Low temp., high temp., low current (current test every 24, 168 or 720 hrs) |
| Alarm outputs | Relays, 5 A at 277 VAC, open or close on alarm |
| Remote output | 4–20 mA process temperature |
| Sensors | 1,000 Ω platinum RTD, 2-wire |
| Ambient | −40° to 113°F |
| Enclosure | NEMA 4X / IP66 polycarbonate |
| Approvals | UL 508, CSA 22.2 #14 |
| Pads | Watts | Amps at 120 V | Controllers |
|---|---|---|---|
| 1 × SPX 210 | 210 | 1.75 | 1 |
| 2 × SPX 210 | 420 | 3.5 | 1 |
| 1 × SPX 210 + 1 × SPX 420 | 630 | 5.25 | 1 |
| 2 × SPX 420 | 840 | 7 | 1 |
| 3 × SPX 420 | 1,260 | 10.5 | 1 |
| 4 × SPX 420 | 1,680 | 14 | 1 |
| 5 × SPX 420 | 2,100 | 17.5 | 1 |
| 6 × SPX 420 | 2,520 | 21 | 1 |
| 7 × SPX 420 | 2,940 | 24.5 | 2 |
| 8 × SPX 420 | 3,360 | 28 | 2 |
| 10 × SPX 420 | 4,200 | 35 | 2 |
How we size a heat trace system
We look at two things:
We have sizing charts for every vertical and double wall tank we sell, for differences from 30°F up to 100°F.
Bigger systems use two controllers, each running half of the pads.
The heat pads go on the tank under the insulation. The tank is hydro-tested before it ships.
Specifications from HTD Heat Trace SPX and 2XTC data sheets. SPX and 2XTC are products of HTD Heat Trace. Specifications subject to change.
Downloads
Heat tracing and insulated, heat-traced tank packages for plastic storage tanks.
Talk to a tank specialist